top of page

DC80E-24110A Model

A powerful Micro Brushless DC pump model, speed adjustable. 24VDC, 120W. Dry run protection, Noise-free, Maintenance-free. 

Rated voltage:                             24VDC

Rated power consumption:           120W

Max static lift:                             11m

Max horizontal flow rate:             4600LPH

Dimension of inlet:        1'' threaded (~32mm)

Dimension of outlet:      1'' threaded (~32mm)

Dimensions:                   144x213.8x147.3mm

Unit weight:                                2.1Kg

Typical Features

  • Powerful pump

  • Speed adjustable, flexible in use

  • Small size with high efficiency, maintenance-free

  • Ceramics shaft and carbon fiber sleeve

  • Completely Waterproof (IP68)

  • Work with very low noise, rather quiet 

  • Brush-less dc control, eco-friendly, stable and long time work 

  • Customization will be supported

  • OEM or ODM will both be supported

  • Relevant control system of pump running can be offered or customized

Dimension of Pump

Dimension photo of DC80E pump.png

Specifications of Pump

  1. Dimension and weight:           144mmx213.8mmx147.3mm; 2.1kg

  2. Dimension of inlet:                   1'' threaded (external diameter ~32mm)

  3. Dimension of outlet:                 1'' threaded (external diameter ~32mm)

  4. Driving mechanism:                 Brushless DC design, Magnetic Separation driving

  5. Rated working voltage:             24V DC 

  6. Allowable working voltage range:                     5-26V DC  

  7. Rated working current:             5A @24VDC

  8. Rated power consumption:     120W @24VDC

  9. Max static lift:                             11m @24VDC (in pressure, ~1.1Kg or 0.11MPa)

  10. Max horizontal flow rate:         4600LPH @24VDC (or, 76.67L/Min)

  11. Material of pump shell:            ABS/PES/SPS/PPS/PA66+30%GF (Optional at customization, PA66+30%GF in default.)

  12. Way of use:                                Land use, or submersible installation (the latter more suitable for version with control circuit designed out of pump body, integrated in control box part.)

  13. Matching medium:                  Water, seawater, oil, alcohol, some weak acid/ alkaline liquids, etc (Special fluids are recommended to be pre-tested.)

  14. Continuous run or not:            Yes. Supports continuous run with stable performance (do not dry run for long time.)

  15. Self-priming or not:                  No. CANNOT be self-priming. 

  16. Waterproof class:                      IP68 (version with control circuit designed out of pump body, intergraded in control box part.)

  17. Noise class:                                Less than 40dB (quiet)

  18. Life span:                                    Can be over 30,000 hours (sufficient in-flow, no dry run. No impurities.)

  19. Working temperature:              -40℃ - 120℃

  20. Matching power supply:          DC battery, Solar panel, AC/DC power adapter, etc (CANNOT be Directly powered by AC power.)

  21. Protection performance:         Dry-run protection (yes in default), Lock-run protection (customization), etc.

  22. Power regulation:                     0-5V analog signal control (supported), potentiometer knob control (supported), PWM signal control (needs to be customized)

Lift-Flow Rate Curve of Pumps

Lift-flow rate curve of pump DC80E -EN.p

Typical Electric Parameters of Pumps

Extra Notes

  • We recommend that our users contact us on info incl. working temperature, matching medium, installation environment before possible order. If you're new customer, sample test will be necessary before possible applications in bulk. 

  • Pump cannot work under corrosive fluids, or higher temperature than declared. Special fluids must be pre-checked or pre-tested. 

  • When pump is installed into circulation system, corresponding load current will be decreased to 70~85% of Max Working Current (namely, Opening Outlet Current).

  • Max Static Lift value means the Max vertical lifting height of water when pump is connected with matching pipe. Flow rate at height of Max Static Lift value is zero. 

  • Max Horizontal Flow Rate value is the flow rate value of pump at horizontal level. (Some users may flowmeter placed at certain location to obtain flow rate value, which is sometimes with rather significant errors.  We recommend that our users to directly measure involved parameters through getting water-volume at horizontal location in time frame of 10 minutes, for example.)

  • Certain parameter deviation shall be taken into consideration when choosing matching pump products, and sufficient margin shall be left.  

  • With typical features of being easy to carry, low noise, continuous stable run and complete safety (low voltage), our pump products have been widely applied in various fileds, including yacht circulation system, auto water-circulation system, medical cooling devices, beauty equipment, plumbing mattresses, solar fountain, computer cooling systems, outdoor camping devices, fueller, humidifier, air conditioner, and various other cooling & circulation systems. 

bottom of page